The Dione S 1280 CAM series is based on an uncooled 12 μm pitch microbolometer detector with a 1280 × 1024 resolution and NETD of less than 40 mK (available upon request) and 50 mK.
The camera cores are optimized for low SWaP (Size, Weight and Power). The Dione S 1280 CAM is lightweight and small with mechanical shutter. It utilizes Xenics image enhancement for advanced image processing while keeping power consumption low.
All Dione S 1280 versions have the same SAMTEC ST5 connector and are GenICam compliant. Dione S 1280 CAM is a LWIR uncooled thermal imaging SWAP module with housing supporting M34/M45 lens (optional).
The ultra-compact Dione S 1280 CAM series find application in safety and security systems, as well as in industrial thermal imaging systems.
Benefits & Features
• State-of-the-art 1280 × 1024 microbolometer detector with 12 μm pitch
• Low SWaP (Size, Weight and Power)
• GenICam compliant
• Shuttered and uncooled operation
• Availability of multiple lenses (optional) adds flexibility to integration programs
Dione S 1280 CAM 40 mK | Dione S 1280 CAM 50 mK | |
Approximate dimensions - excluding lens [width x height x length] [mm] | 60 x 55 x 39* | 65 x 62 x 40* | 60 x 55 x 39* | 65 x 62 x 40* |
Weight [gr] - excluding lens | 188* | 190* | 188* | 190* |
Optical interface (optional) | M34x0.5 or M45x0.75 | M34x0.5 or M45x0.75 |
Connector general I/O | SAMTEC ST5-30-1.50-L-D-P-TR | SAMTEC ST5-30-1.50-L-D-P-TR |
Dione S 1280 CAM 40 mK | Dione S 1280 CAM 50 mK | |
Ambient operating temperature range [°C] | From -40 to +70 | From -40 to +70 |
Storage temperature [°C] | From -45 to +85 | From -45 to +85 |
Power consumption [W] | 2.3 (at 60 Hz operation; 16bitDV) | 2.3 (at 60 Hz operation; 16bitDV) |
Power supply voltage | DC 5 V | DC 5 V |
Shock | 40 g, 11 ms, MIL-STD810G | 40 g, 11 ms, MIL-STD810G |
Vibration | 5 g [20 to 2000 Hz], MIL-STD810G | 5 g [20 to 2000 Hz], MIL-STD810G |
Regulatory compliance | RoHS | RoHS |
Dione S 1280 CAM 40 mK | Dione S 1280 CAM 50 mK | |
Image format [pixels] | 1280 x 1024 | 1280 x 1024 |
Pixel pitch [µm] | 12 | 12 |
Detector type | Microbolometer | Microbolometer |
Integration type | Rolling shutter | Rolling shutter |
Active area and diagonal [mm] | 15.36 x 12.29 [19.67 diagonal] | 15.36 x 12.29 [19.67 diagonal] |
Detector NETD [Noise Equivalent Temperature Difference] [mK] | <40 [at 30 Hz, 300K, F/1], available upon request | <50 [at 30 Hz, 300K, F/1] |
Spectral range [µm] | 8 - 14 | 8 - 14 |
Pixel operability | >99.5% | >99.5% |
Max frame rate [full frame] [Hz] | 60 | 60 |
Integration time range [µs] | 20 – 65 (1 – 65 µs is possible) | 20 – 65 (1 – 65 µs is possible) |
Region of interest | Yes | Yes |
Min region size [pixels] | 80 x 80 | 80 x 80 |
Analog-to-Digital [ADC] [bits] | 14 | 14 |
Command and control | SAMTEC ST5 connector | SAMTEC ST5 connector |
Digital output format | 16bit DV**, MIPI CSI-2**, USB** | 16bit DV**, MIPI CSI-2**, USB** |
Trigger | SAMTEC ST5 connector | SAMTEC ST5 connector |